Panel Radiator Output Calculator (EN 442) | Muhendis Portal

Calculate required panel radiator length and heating capacity (Watt / kcal/h) for rooms based on area, ceiling height and EN 442 temperature regimes.

Verified Engineering Calculation Engine

Engineered for mechanical, HVAC, piping, and design engineers in compliance with international standards (ISO, DIN, EN, ASME, ASHRAE). Load the interactive tool for real-time calculations and automated reports.

EN 442 Type 22 (PKKP H=600 mm) Panel Radiator Length & Heat Output Chart

Thermal output in Watts and kcal/h for standard 75/65/20°C and low-temperature condensing 55/45/20°C regimes.

Room Area (m²)Radiator Length (Type 22)Output at 75/65/20°C (W)Output at 75/65/20°C (kcal/h)Condensing 55/45/20°C (W)
8 – 10 m²600 mm (0.6 m)1,004 W863 kcal/h518 W
11 – 14 m²800 mm (0.8 m)1,339 W1,151 kcal/h691 W
15 – 17 m²1000 mm (1.0 m)1,674 W1,440 kcal/h864 W
18 – 21 m²1200 mm (1.2 m)2,009 W1,728 kcal/h1,037 W
22 – 25 m²1400 mm (1.4 m)2,344 W2,016 kcal/h1,210 W
26 – 30 m²1600 mm (1.6 m)2,678 W2,303 kcal/h1,382 W
31 – 36 m²2000 mm (2.0 m)3,348 W2,879 kcal/h1,728 W

Frequently Asked Questions (FAQ)

What is standard EN 442 Delta-T 50°C?

EN 442 rates radiators at 75°C flow, 65°C return and 20°C room temperature, yielding an arithmetic mean temperature difference (Delta-T) of 50°C.