Building Thermal Insulation & U-Value Calculation Guide (TS 825 / ISO 6946)
How to calculate overall thermal transmittance (U-value) and select optimal insulation thickness using EPS, XPS, or Rockwool under TS 825 and EN ISO 6946.
Minimizing heating and cooling energy demand in buildings requires strict compliance with thermal insulation standards such as TS 825 and EN ISO 6946.
Thermal Transmittance (U-Value) and Resistance (R)
The overall heat transfer coefficient (U-value, in W/m²·K) measures the rate of heat transfer through 1 m² of a building envelope element per degree Kelvin temperature difference:
U = 1 / (Rsi + R1 + R2 + ... + Rn + Rse)
Each layer's conductive thermal resistance is calculated from its thickness (d, m) and thermal conductivity (λ, W/m·K):
R = d / λ
Comparing EPS, XPS, and Rockwool
- EPS (Expanded Polystyrene): Cost-effective facade insulation (λ ≈ 0.035–0.040 W/m·K).
- XPS (Extruded Polystyrene): High compressive strength and low moisture absorption (λ ≈ 0.030–0.035 W/m·K), ideal for foundations and inverted roofs.
- Rockwool (Mineral Wool): Class A1 non-combustible fire resistance with superior acoustic damping (λ ≈ 0.035–0.040 W/m·K).
Check condensation risk and required thickness instantly with our Building Thermal Insulation Calculator.