Building Thermal Insulation Calculator | Muhendis Portal

Calculate thermal transmittance (U-value) for multi-layer walls, roofs and floors, and verify required insulation thickness (EPS, XPS, mineral wool).

Verified Engineering Calculation Engine

Engineered for mechanical, HVAC, piping, and design engineers in compliance with international standards (ISO, DIN, EN, ASME, ASHRAE). Load the interactive tool for real-time calculations and automated reports.

TS 825 / EN ISO 6946 Maximum Permitted U-Values by Climate Zone

Maximum permissible thermal transmittance U (W/m²·K) for external walls, roofs, floors, and windows across degree-day zones.

Climate ZoneRepresentative CitiesWall Umax (W/m²·K)Roof Umax (W/m²·K)Floor Umax (W/m²·K)Window Umax (W/m²·K)
Zone 1 (Warm)Antalya, Izmir, Adana0.660.430.661.80
Zone 2 (Temperate)Istanbul, Bursa, Kocaeli0.570.380.571.80
Zone 3 (Continental)Ankara, Konya, Eskisehir0.480.280.431.80
Zone 4 (Cold)Kayseri, Sivas, Van0.380.230.381.80
Zone 5 (Severe Cold)Erzurum, Kars, Agri0.360.210.361.80

Frequently Asked Questions (FAQ)

What is U-value in building physics?

The U-value (W/m²·K) measures the rate of heat transfer through a structure divided by the difference in temperature across that structure. Lower U-values indicate better insulation.