Welded Joint Strength & Throat Sizing | Muhendis Portal

Verify fillet weld throat thickness (a), longitudinal shear stress and transverse tensile allowable loads according to Eurocode 3 and AWS D1.1.

Verified Engineering Calculation Engine

Engineered for mechanical, HVAC, piping, and design engineers in compliance with international standards (ISO, DIN, EN, ASME, ASHRAE). Load the interactive tool for real-time calculations and automated reports.

EN 1993-1-8 (Eurocode 3) Fillet Weld Throat Thickness & Design Resistance Chart

Fillet weld throat thickness (a), leg length (z), and design shear resistance per centimeter (kN/cm) for S235 and S355 steels.

Throat Thickness a (mm)Leg Length z = √2·a (mm)S235 Capacity (kN/cm)S355 Capacity (kN/cm)Typical Electrode Dia (mm)
a = 3.0 mm4.2 mm6.2 kN/cm7.5 kN/cmØ 2.5 mm
a = 4.0 mm5.7 mm8.3 kN/cm10.0 kN/cmØ 3.25 mm
a = 5.0 mm7.1 mm10.4 kN/cm12.5 kN/cmØ 3.25 – 4.0 mm
a = 6.0 mm8.5 mm12.5 kN/cm15.0 kN/cmØ 4.0 mm
a = 8.0 mm11.3 mm16.6 kN/cm20.0 kN/cmMulti-pass / GMAW

Frequently Asked Questions (FAQ)

What is the throat thickness (a) of a fillet weld?

The effective throat thickness is the shortest distance from the root of the joint to the face of the diagrammatic weld, typically a = leg length / √2 (approx. 0.707 × s).

Related Technical Guides