Natural Gas Pipe Sizing Methods & Pressure Drop Rules
Accurate natural gas pipe sizing is essential for safety and compliance. Learn critical line pressure drop and velocity limits under TS 7363 / EN 1775.
Proper sizing of natural gas piping ensures that all gas appliances receive fuel at the required operating pressure and volumetric flow rate safely.
Operating Pressure and Velocity Limits
Residential and commercial installations typically operate at 21 mbar (low pressure) or 300 mbar (medium pressure risers). Under TS 7363 and EN 1775 standards, total pressure drop between the meter and the farthest appliance must remain below permissible limits (typically ΔP ≤ 1.0 to 1.8 mbar for 21 mbar networks), and gas velocity must not exceed 6 m/s in residential zones to prevent acoustic noise and erosion.
Critical Line and Pressure Loss Formula
Pipe sizing is evaluated along the critical line—the longest path with the highest fitting resistance:
ΔP = R × L + Z
- R: Linear friction pressure loss per meter (mbar/m)
- L: Straight pipe length (m)
- Z: Local pressure drop across elbows, tees, and valves (mbar)
Use our interactive Natural Gas Pipe Sizing Calculator to size risers and branch lines automatically.