How do you size a compressed air receiver tank?
Air receiver volume depends on compressor FAD capacity, cut-in/cut-out pressure band (ΔP), and maximum allowable load/unload cycles per hour.
Calculate compressed air demand (FAD m³/min & CFM), air receiver tank volume (Liters), and estimated screw compressor motor power (kW).
Engineered for mechanical, HVAC, piping, and design engineers in compliance with international standards (ISO, DIN, EN, ASME, ASHRAE). Load the interactive tool for real-time calculations and automated reports.
Approximate free air delivery (FAD) at 7.5–8 bar operating pressure and recommended buffer tank sizes.
| Motor Power (kW / HP) | Air Flow (m³/min) | Air Flow (CFM) | Recommended Tank (Liters) |
|---|---|---|---|
| 7.5 kW (10 HP) | 1.10 – 1.25 m³/min | 39 – 44 CFM | 500 L |
| 15 kW (20 HP) | 2.20 – 2.50 m³/min | 78 – 88 CFM | 1,000 L |
| 22 kW (30 HP) | 3.40 – 3.80 m³/min | 120 – 134 CFM | 1,500 – 2,000 L |
| 37 kW (50 HP) | 5.80 – 6.40 m³/min | 205 – 226 CFM | 2,000 – 3,000 L |
| 55 kW (75 HP) | 8.80 – 9.60 m³/min | 310 – 339 CFM | 3,000 – 4,000 L |
| 75 kW (100 HP) | 12.0 – 13.2 m³/min | 424 – 466 CFM | 5,000 L |
Air receiver volume depends on compressor FAD capacity, cut-in/cut-out pressure band (ΔP), and maximum allowable load/unload cycles per hour.