What does bolt grade 8.8 mean?
The first number (8) multiplied by 100 gives the nominal tensile strength (800 N/mm²). The second number (.8) multiplied by the first gives the yield strength (800 × 0.8 = 640 N/mm²).
Calculate tensile and shear load capacities, tightening torque and safety factors for metric bolts according to ISO 898-1.
Engineered for mechanical, HVAC, piping, and design engineers in compliance with international standards (ISO, DIN, EN, ASME, ASHRAE). Load the interactive tool for real-time calculations and automated reports.
Minimum tensile strength (Rm), yield strength (Re / Rp0.2), proof load stress (Sp), and M12 yield load capacity.
| Property Class | Tensile Strength Rm (MPa) | Yield Strength Re (MPa) | Proof Stress Sp (MPa) | Shear Stress τ ≈ 0.6·Re (MPa) | M12 (As=84.3 mm²) Yield Load (kN) |
|---|---|---|---|---|---|
| 4.6 | 400 | 240 | 225 | 144 | 20.2 kN |
| 5.8 | 500 | 400 | 380 | 240 | 33.7 kN |
| 8.8 | 800 | 640 | 580 | 384 | 54.0 kN |
| 10.9 | 1000 | 900 | 830 | 540 | 75.9 kN |
| 12.9 | 1200 | 1080 | 970 | 648 | 91.0 kN |
| A2-70 (Stainless) | 700 | 450 | 410 | 270 | 37.9 kN |
The first number (8) multiplied by 100 gives the nominal tensile strength (800 N/mm²). The second number (.8) multiplied by the first gives the yield strength (800 × 0.8 = 640 N/mm²).